← Search

Joonhwan Kim

8 accepted papers

2021

A Sigmoid-Colon-Straightening Soft Actuator With Peristaltic Motion for Colonoscopy Insertion Assistance: Easycolon

RA-L 2021

A colonoscopy is the most typical method to inspect for colorectal cancer; however, inserting colonoscopes in nonfixed sites, such as the sigmoid colon, requires very skilled insertion techniques. Since the sigmoid colon is one of the most difficult nonfixed sites for insertion, straightening it is

Cited by 13SourceScholar
2021

Correction to "A Sigmoid-Colon-Straightening Soft Actuator With Peristaltic Motion for Colonoscopy Insertion Assistance: Easycolon"

RA-L 2021

There are two corresponding authors who have contributed to this letter, yet only one of them has been mentioned as the corresponding author in the original letter. As a result, “Ki-Uk Kyung” was added to footnote as a co-corresponding author. The changes have been reflected as follows.

Cited by 0SourceScholar
2021

Design and Analysis of High-Stiffness Hyperredundant Manipulator With Sigma-Shaped Wire Path and Rolling Joints

RA-L 2021

High stiffness is desirable for wire-driven underactuated hyperredundant manipulators used in minimally invasive surgery. However, limited structural stiffness can cause lateral and angular deflections by the lateral force and moment applied to the distal end of the manipulator. This letter proposes

Cited by 18SourceScholar
2020

Hysteresis Compensator With Learning-Based Hybrid Joint Angle Estimation for Flexible Surgery Robots

RA-L 2020

Hysteresis causes difficulties in precisely controlling motion of flexible surgery robots and degrades the surgical performance. In order to reduce hysteresis, model-based feed-forward and feedback-based methods using endoscopic cameras have been suggested. However, model-based methods show limited

Cited by 19SourceScholar
2020

Payload optimization of surgical instruments with rolling joint mechanisms

IROS 2020poster

Many surgical robots with steerable surgical instruments have been proposed for endoscopic surgery. Surgical instruments should be small in size for insertion into the body and be able to handle large payloads such as tissue. Because the overall diameter and payload parameters are a trade-off, it is…

Cited by 14SourceScholar
2019

Hysteresis Compensator with Learning-based Pose Estimation for a Flexible Endoscopic Surgery Robot

IROS 2019poster

The use of the tendon-sheath mechanism (TSM) is common in flexible surgery robots, because it can flexibly work in limited spaces and provides efficient power transmission. However, hysteresis from nonlinearities such as friction and backlash poses a challenge in controlling precise motion in the su…

Cited by 10SourceScholar
2019

Shape-Locking Mechanism of Flexible Joint Using Mechanical Latch With Electromagnetic Force

RA-L 2019

Single-incision laparoscopic surgery (SILS) has emerged as a procedure to further improve cosmetic profits and reduce the postoperative pain of multiport laparoscopic surgery. However, SILS is a difficult operation due to the limited workspace or accessibility. To improve surgical convenience, flexi

Cited by 20SourceScholar
2019

Three-Degrees-of-Freedom Passive Gravity Compensation Mechanism Applicable to Robotic Arm With Remote Center of Motion for Minimally Invasive Surgery

RA-L 2019

For safety enhancement reasons, passive gravity compensation is widely applied in robotic systems used in minimally invasive surgery (MIS). MIS robotic systems have a remote center of motion (RCM) in which a surgical instrument conducts a fulcrum motion around a point of invasion. RCM mechanisms inc

Cited by 24SourceScholar