← Search

Keith L. Obstein

11 accepted papers

2024

A Robotic Mediation Device for Skill Assessment and Training During Colonoscopy

IROS 2024poster

Colonoscopy demands multi-finger coordinated motion to achieve safe navigation. As a result, training for colonoscopists is challenging and skill assessment currently relies on subjective scoring by expert proctors. There is a need to provide tools for skill assessment and aid with training new inte…

Cited by 0SourceScholar
2023

Wireless Millimeter-Size Soft Climbing Robots With Omnidirectional Steerability on Tissue Surfaces

RA-L 2023

Wirelessly actuated miniature soft robots actuated by magnetic fields that can overcome gravity by climbing soft and wet tissues are promising for accessing challenging enclosed and confined spaces with minimal invasion for targeted medical operation. However, existing designs lack the directional s

Cited by 13SourceScholar
2020

Online Disturbance Estimation for Improving Kinematic Accuracy in Continuum Manipulators

RA-L 2020

Continuum manipulators are flexible robots which undergo continuous deformation as they are actuated. To describe the elastic deformation of such robots, kinematic models have been developed and successfully applied to a large variety of designs and to various levels of constitutive stiffness. Indep

Cited by 22SourceScholar
2020

Teleoperation and Contact Detection of a Waterjet-Actuated Soft Continuum Manipulator for Low-Cost Gastroscopy

RA-L 2020

Gastric cancer is the third leading cause of cancer deaths worldwide, with most new cases occurring in low and middle income countries, where access to screening programs is hindered by the high cost of conventional endoscopy. The waterjet-actuated HydroJet endoscopic platform was developed as a low

Cited by 19SourceScholar
2019

Adaptive Dynamic Control for Magnetically Actuated Medical Robots

RA-L 2019

In the present work we discuss a novel dynamic control approach for magnetically actuated robots, by proposing an <i>adaptive control</i> technique, robust towards parametric uncertainties and unknown bounded disturbances. The former generally arise due to partial knowledge of the robots' dynamic pa

Cited by 58SourceScholar
2019

Explicit Model Predictive Control of a Magnetic Flexible Endoscope

RA-L 2019

In this paper, explicit model predictive control is applied in conjunction with nonlinear optimisation to a magnetically actuated flexible endoscope for the first time. The approach is aimed at computing the motion of the external permanent magnet, given the desired forces and torques. The strategy

Cited by 27SourceScholar
2019

Magnetic Levitation for Soft-Tethered Capsule Colonoscopy Actuated With a Single Permanent Magnet: A Dynamic Control Approach

RA-L 2019

The present letter investigates a novel control approach for magnetically driven soft-tethered capsules for colonoscopy-a potentially painless approach for colon inspection. The focus of this work is on a class of devices composed of a magnetic capsule endoscope actuated by a single external permane

Cited by 116SourceScholar
2019

Sensorless Estimation of the Planar Distal Shape of a Tip-Actuated Endoscope

RA-L 2019

Traditional endoscopes consist of a flexible body and a steerable tip with therapeutic capability. Although prior endoscopes have relied on operator pushing for actuation, recent robotic concepts have relied on the application of a tip force for guidance. In such case, the body of the endoscope can

Cited by 4SourceScholar
2017

Autonomous Retroflexion of a Magnetic Flexible Endoscope

RA-L 2017

Retroflexion during colonoscopy is typically only practiced in the wider proximal and distal ends of the large intestine owing to the stiff nature of the colonoscope. This inability to examine the proximal side of the majority of colon folds contributes to today's suboptimal colorectal cancer detect

Cited by 33SourceScholar
2016

Closed Loop Control of a Tethered Magnetic Capsule Endoscope

RSS 2016poster

Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force varia- tion with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robot…

Cited by 36SourcePDFScholar
2016

Nonholonomic closed-loop velocity control of a soft-tethered magnetic capsule endoscope

IROS 2016poster

In this paper, we demonstrate velocity-level closed-loop control of a tethered magnetic capsule endoscope that is actuated via serial manipulator with a permanent magnet at its end-effector. Closed-loop control (2 degrees-of-freedom in position, and 2 in orientation) is made possible with the use of…

Cited by 36SourceScholar