← Search

Hideki Kadone

6 accepted papers

2024

A Neck Orthosis With Multi-Directional Variable Stiffness for Persons With Dropped Head Syndrome

RA-L 2024

Dropped Head Syndrome (DHS) causes a passively correctable neck deformation. Currently, there is no wearable orthopedic neck brace to fulfill the needs of persons suffering from DHS. Related works have made progress in this area by creating mobile neck braces that provide head support to mitigate de

Cited by 5SourceScholar
2021

Passive Flow Control for Series Inflatable Actuators: Application on a Wearable Soft-Robot for Posture Assistance

RA-L 2021

This letter presents a passive control method for multiple degrees of freedom in a soft pneumatic robot through the combination of flow resistor tubes with series inflatable actuators. We designed and developed these 3D printed resistors based on the pressure drop principle of multiple capillary ori

Cited by 12SourceScholar
2020

Control Interface for Hands-free Navigation of Standing Mobility Vehicles based on Upper-Body Natural Movements

IROS 2020poster

In this paper, we propose and evaluate a novel human-machine interface (HMI) for controlling a standing mobility vehicle or person carrier robot, aiming for a hands-free control through upper-body natural postures derived from gaze tracking while walking. We target users with lower-body impairment w…

Cited by 13SourceScholar
2019

MRLift: a Semi-active Lower Back Support Exoskeleton based on MR Fluid and Force Retention Technology

IROS 2019poster

Wearable robots suffer from issues of usability, cost-performance, and battery life. These drawbacks hinder the development of their market and their implementation in healthcare and industry. Back support exoskeletons in particular rely heavily on mechanical storing of energy but are still mostly u…

Cited by 19SourceScholar
2018

A Synergetic Voluntary Control for Exoskeleton based on Spinal Cord Mapping of Peripheral Bioelectric Activity

IROS 2018poster

Walking rehabilitation must be performed based on voluntary motion intention, and for this purpose, the development of a control method for an exoskeleton robot based on voluntary intention is investigated. This study proposes a method of exoskeleton robot control to estimate the voluntary lower lim…

Cited by 1SourceScholar
2018

Unpowered Lower-Body Exoskeleton with Torso Lifting Mechanism for Supporting Sit-to-Stand Transitions

IROS 2018poster

In this paper, we propose the design of an exoskeleton with support at the knee joint and lower torso for sit-to-stand and stand-to-sit (STS) posture transitions; devised for users with spinal cord injury and other complete lower-body impairments. The STS transitions assistance is achieved through a…

Cited by 40SourceScholar