← Search

James M. Drake

7 accepted papers

2025

A Compact Dual-Mode Twisting Retraction Device for Endoscopic Submucosal Dissection

IROS 2025

Endoscopic submucosal dissection (ESD) is a technically difficult, minimally invasive, organ preserving resection technique that yields improved clinical outcomes when compared to current conventional procedures but requires experienced surgeons and specialized skills. Difficulty in applying tension

Cited by 0SourceScholar
2025

A Da Vinci Open Spina Bifida Suturing Simulator with Continuum Tools for Surgeon Skills Training

IROS 2025

Open Spina Bifida (OSB) is a congenital neural tube defect that affects approximately 1 in 1000 births worldwide. Robotic in-utero OSB repair provides a minimally invasive alternative to open-surgery, which places significant strain on both baby and mother. Recent advancements in da Vinci miniature

Cited by 0SourceScholar
2025

Learning-Based Tip Contact Force Estimation for FBG-Embedded Continuum Robots

ICRA 2025

Knowledge of the tip contact force in continuum robots, which are often used as medical instruments, is critical for clinical applications. It enhances the interventionalist's decision-making, navigation efficiency, and procedural safety. However, accurately determining the tip contact force in conv

Cited by 2SourceScholar
2022

Robust Sim2Real Transfer with the da Vinci Research Kit: A Study On Camera, Lighting, and Physics Domain Randomization

IROS 2022poster

Autonomous surgical robotics is a growing area of research, with advances being made in the areas of vision and control. Central to this research is the need for simulations to facilitate data collection and simulate learning environments for Reinforcement Learning (RL) agents. Recent simulators hav…

Cited by 7SourceScholar
2019

Cable-Less, Magnetically Driven Forceps for Minimally Invasive Surgery

RA-L 2019

In this letter, a novel end-effector for surgical applications is presented that uses magnetic actuation in lieu of a more traditional cable-driven tool with the goal of providing high dexterity in hard-to-reach locations by decoupling the tool actuation from the rest of the surgical system. The gri

Cited by 36SourceScholar
2016

Kinetostatic design of asymmetric notch joints for surgical robots

IROS 2016poster

We present a kinetostatic model for a needle-sized notched tube continuum joint design, and examine the impact that the design parameters have on both stiffness and joint kinematics. The joint is fabricated by removing a series of asymmetric notches from a metal tube. By fixing a cable to the distal…

Cited by 39SourceScholar