← Search

Lin Cao

11 accepted papers

2026

Robust Admittance Control of an Electric Underwater Manipulator for Precise Motion and Safe Contact Inspection of Hydraulic Structures

ICRA 2026poster

Inspection of hydraulic structures is crucial for ensuring the reliability and safety of infrastructures. Although underwater manipulators are essential tools, existing systems often lack sufficient compliance and safe interaction capabilities. This study develops a novel underwater manipulator syst…

Cited by 0SourceScholar
2025

Multi-View Normal and Distance Guidance Gaussian Splatting for Surface Reconstruction

IROS 2025

3D Gaussian Splatting (3DGS) achieves remarkable results in the field of surface reconstruction. However, when Gaussian normal vectors are aligned within the single-view projection plane, while the geometry appears reasonable in the current view, biases may emerge upon switching to nearby views. To

Cited by 0SourceScholar
2025

Robotic Colonoscopy: Can High Fidelity Simulation Optimize Robot Design and Validation?

ICRA 2025

This paper presents the use of a simulation environment as an accurate, ethical, and sustainable alternative to testing robotic prototypes in animal models and simplified phantom models, specifically developed for robotic colonoscopy devices inside the human colon. A virtual simulation of the locomo

Cited by 1SourceScholar
2021

Design and Evaluation of a Foot-Controlled Robotic System for Endoscopic Surgery

RA-L 2021

In traditional endoscopic surgery, the surgeon manipulating the endoscopic instruments is supported by an assistant controlling the endoscope, where their coordination may be affected by communication errors. To address this issue, we introduce a foot interface controlled robotic endoscopic system,

Cited by 21SourceScholar
2020

Joint Rotation Angle Sensing of Flexible Endoscopic Surgical Robots

ICRA 2020poster

Accurate motion control of surgical robots is critical for the efficiency and safety of both state-of-the-art teleoperated robotic surgery and the ultimate autonomous robotic surgery. However, fine motion control for a flexible endoscopic surgical robot is highly challenging because of the shape-dep…

Cited by 10SourceScholar
2019

A Novel Robotic Suturing System for Flexible Endoscopic Surgery

ICRA 2019poster

Perforations in flexible endoscopy are life-threatening. Defect closure or suturing in flexible endoscopy has long been a critical challenge due to the confined space of the access routes and surgical sites, high dexterity and force demands of suturing tasks, as well as critical size and strength re…

Cited by 36SourceScholar
2019

Performance Evaluation of a Foot Interface to Operate a Robot Arm

RA-L 2019

We developed a foot interface enabling an operator to control a robotic arm with four degrees of freedom in continuous direction and speed, for operating one of the multiple tools required during robot-aided surgery. In this letter, we first test whether this pedal interface can be used to carry out

Cited by 19SourceScholar
2019

Pneumatically Actuated Deployable Tissue Distension Device for NOTES for Colon

ICRA 2019poster

When performing some surgical tasks inside colon with NOTES technology, colon tissue could block the task space and occlude the endoscopic vision. In order to solve this problem, we developed a pneumatically driven deployable and undeployable structure which can distend collapsing tissue and can be…

Cited by 6SourceScholar
2018

Distal End Force Sensing with Optical Fiber Bragg Gratings for Tendon-Sheath Mechanisms in Flexible Endoscopic Robots

ICRA 2018poster

Accurate haptic feedback is a critical challenge for surgical robots, especially for flexible endoscopic surgical robots whose transmission systems are Tendon-Sheath Mechanisms (TSMs) with highly nonlinear friction profiles and force hysteresis. For distal end haptic sensing of TSMs, this paper, for…

Cited by 41SourceScholar