← Search

Muneaki Miyasaka

11 accepted papers

2024

Preliminary Study of Fingertip and Wrist Motion Based Haptic Controller for Robotically Assisted Micro- and Supermicrosurgery

ICRA 2024poster

One issue of robotic microsurgery is that compared to manual surgery, the operation time tends to be longer due to high motion scaling. To address this issue, we developed a new controller that can provide the accuracy required for microsurgery without a high scaling factor by utilizing fingertip an…

Cited by 0SourceScholar
2019

Pneumatically Actuated Deployable Tissue Distension Device for NOTES for Colon

ICRA 2019poster

When performing some surgical tasks inside colon with NOTES technology, colon tissue could block the task space and occlude the endoscopic vision. In order to solve this problem, we developed a pneumatically driven deployable and undeployable structure which can distend collapsing tissue and can be…

Cited by 6SourceScholar
2017

Improving control precision and motion adaptiveness for surgical robot with recurrent neural network

IROS 2017poster

Surgical robot research is driven by the desire of improving surgical outcomes. This paper proposed a Recurrent Neural Network based controller to address two problems: 1) improving control precision, 2) increasing adaptiveness for robot motion (explained in Section I). RNN was adopted in this work…

Cited by 34SourceScholar
2017

Integrated asymmetric stop operator based model for strain stress hysteresis characteristics of cable driven robots loaded longitudinally

IROS 2017poster

Beside the output-input hysteresis, the longitudinally loaded cables of medical robotics such as RAVEN II exhibit asymmetric saturated strain-load hysteresis loops. This study investigates modeling the hysteresis nonlinearities of these cables using a stop-operator based Prandtl-Ishlinskii (SPI) mod…

Cited by 6SourceScholar
2017

Roboscope: A flexible and bendable surgical robot for single portal Minimally Invasive Surgery

ICRA 2017poster

Minimally Invasive Surgery (MIS) can reduce iatrogenic injury and decrease the possibility of surgical complications. This paper presents a novel flexible and bendable endoscopic device, “Roboscope”, which delivers two instruments, two miniature scanning fiber endoscopes, and a suction/irrigation po…

Cited by 45SourceScholar
2017

Utilizing Elasticity of Cable-Driven Surgical Robot to Estimate Cable Tension and External Force

RA-L 2017

Cable-driven robots enable compact design by allowing actuators to be mounted away from joints. This kind of actuation is desired in surgical robots. The cables in these robots must remain under tension at all times in order to have optimum performance. Thus, the knowledge of initial value of cable

Cited by 46SourceScholar
2016

Dynamic modeling of cable driven elongated surgical instruments for sensorless grip force estimation

ICRA 2016

Haptic feedback plays a key role in surgeries, but it is still a missing component in robotic Minimally Invasive Surgeries. This paper proposes a dynamic model-based sensorless grip force estimation method to address the haptic perception problem for commonly used elongated cable-driven surgical ins

Cited by 46SourceScholar
2016

Hysteresis model of longitudinally loaded cable for cable driven robots and identification of the parameters

ICRA 2016

In this paper, we propose model of longitudinally loaded cable based on the Bouc-Wen hysteresis model and within the framework of the Duhem operator. By optimizing the 9 hysteresis model parameters with a genetic algorithm, the proposed model is shown to be capable of representing quasi-static respo

Cited by 50SourceScholar
2016

Unscented Kalman Filter and 3D vision to improve cable driven surgical robot joint angle estimation

ICRA 2016

Cable driven manipulators are popular in surgical robots due to compact design, low inertia, and remote actuation. In these manipulators, encoders are usually mounted on the motor, and joint angles are estimated based on transmission kinematics. However, due to non-linear properties of cables such a

Cited by 36SourceScholar
2015

Improving position precision of a servo-controlled elastic cable driven surgical robot using Unscented Kalman Filter

IROS 2015poster

Cable driven power transmission is popular in many manipulator applications including medical arms. In spite of advantages obtained by removing motors from the mechanism, cable transmission introduces higher non-linearity and more uncertainties such as cable stretch and cable coupling. In order to i…

Cited by 56SourceScholar
2015

Measurement of the cable-pulley Coulomb and viscous friction for a cable-driven surgical robotic system

IROS 2015poster

In this paper we present experimentally obtained cable-pulley Coulomb and viscous friction for cable-driven surgical robotic systems including the RAVEN II surgical robotic research platform. In the study of controlling cable-driven systems a simple mathematical model which does not capture physical…

Cited by 65SourceScholar