← Search

S. Farokh Atashzar

12 accepted papers

2024

From Unstable Electrode Contacts to Reliable Control: A Deep Learning Approach for HD-sEMG in Neurorobotics

ICRA 2024poster

In the past decade, there has been significant advancement in designing wearable neural interfaces for controlling neurorobotic systems, particularly bionic limbs. These interfaces function by decoding signals captured noninvasively from the skin’s surface. Portable high-density surface electromyogr…

Cited by 1SourceScholar
2023

A Smart Handheld Edge Device for on-Site Diagnosis and Classification of Texture and Stiffness of Excised Colorectal Cancer Polyps

IROS 2023poster

This paper proposes a smart handheld textural sensing medical device with complementary Machine Learning (ML) algorithms to enable on-site Colorectal Cancer (CRC) polyp diagnosis and pathology of excised tumors. The proposed unique handheld edge device benefits from a unique tactile sensing module a…

Cited by 6SourceScholar
2023

CogniDaVinci: Towards Estimating Mental Workload Modulated by Visual Delays During Telerobotic Surgery - An EEG-based Analysis

ICRA 2023poster

Communication latency in any delicate telerobotic operation (such as remote surgery over distance) would impose a significant challenge due to the temporal degradation of visual perception and can substantially affect the outcomes. Less is known, however, about the neurophysiological basis of how op…

Cited by 4SourceScholar
2023

Design Optimization and Data-driven Shallow Learning for Dynamic Modeling of a Smart Segmented Electroadhesive Clutch

ICRA 2023poster

Electroadhesive clutches have attracted a great deal of interest in the last decade as semi-active actuators for human-robot interaction due to their lightweight, low power consumption, and tunable high-torque output capability. However, because of the complexity of their dynamics, in most cases, th…

Cited by 0SourceScholar
2023

Harnessing the Power of Human Biomechanics in Force-Position Domain: A 3D Passivity Index Map for Upper Limb Physical Human-(Tele) Robot Interaction

IROS 2023poster

In the context of physical human-(tele)robot interaction, passivity-based stabilizers have been used to guarantee the physical or (tele) physical stability. In most of these examples, human biomechanics is considered an inherently passive system that dissipates energy. This assumption may not hold t…

Cited by 1SourceScholar
2023

On the Potentials of Surface Tactile Imaging and Dilated Residual Networks for Early Detection of Colorectal Cancer Polyps

IROS 2023poster

This study proposes a novel diagnosis framework to decrease the early detection miss rate of colorectal cancer (CRC) polyps by using a hypersensitive vision-based tactile sensor (HySenSe) and a deep residual neural network. The HySenSe generates high-resolution 3D textural images of 160 realistic po…

Cited by 6SourceScholar
2023

The MyoPassivity Puzzle: How Does Muscle Fatigue Affect Energetic Behavior of the Human Upper-Limb During Physical Interaction with Robots?

IROS 2023poster

The human limb possesses a remarkable capacity to absorb energy during physical human-robot interaction (pHRI), which can be quantified as the biomechanical “Excess of Passivity” (EoP) using non-linear control theory. This biome-chanical passivity index can be used to reduce conservatism and increas…

Cited by 1SourceScholar
2023

Upper-limb Geometric MyoPassivity Map for Physical Human-Robot Interaction

ICRA 2023poster

The intrinsic biomechanical characteristic of the human upper limb plays a central role in absorbing the interactive energy during physical human-robot interaction (pHRI). We have recently shown that based on the concept of “Excess of Passivity (EoP),” from nonlinear control theory, it is possible t…

Cited by 3SourceScholar
2022

Deep Augmentation for Electrode Shift Compensation in Transient High-density sEMG: Towards Application in Neurorobotics

IROS 2022poster

Going beyond the traditional sparse multi-channel peripheral human-machine interface that has been used widely in neurorobotics, high-density surface electromyography (HD-sEMG) has shown significant potential for decoding upper-limb motor control. We have recently proposed heterogeneous temporal dil…

Cited by 12SourceScholar
2021

Time-Domain Passivity-based Controller with an Optimal Two-channel Lawrence Telerobotic Architecture

ICRA 2021poster

The time-domain passivity approach has been proposed in the literature in a variety of formats to guarantee the stability of teleoperation leader-follower systems. The conventional use of the proposed technique utilizes the control effort at the follower side as the force feedback to be sent back to…

Cited by 3SourceScholar
2015

A new passivity-based control technique for safe patient-robot interaction in haptics-enabled rehabilitation systems

IROS 2015poster

In this paper, a new passivity-based technique is proposed to analyze and guarantee the stability of haptics-enabled telerobotic rehabilitation systems where there is a possibility of having more sources of non-passivity than communication delays. In practice, the difficulty of therapeutic exercises…

Cited by 23SourceScholar
2015

Therapist-in-the-Loop robotics-assisted mirror rehabilitation therapy: An Assist-as-Needed framework

ICRA 2015poster

This paper presents a Therapist-in-the-Loop (TIL) framework for robotics-assisted mirror rehabilitation therapy integrated with adaptive Assist-as-Needed (ANN) training, to be adjusted based on the impairment and disability level of the patient's affected limb. Closed-loop system stability has been…

Cited by 10SourceScholar