Guillaume Morel

17 accepted papers

2025

A Comparative Study Between a Virtual Wand and a One-to-One Approach for the Teleoperation of a Nearby Robotic Manipulator

ICRA 2025

The prevailing and most effective approach to teleoperate a robotic arm involves a direct position-to-position mapping, imposing robotic end-effector movements that mirrors those of the user, Fig. 1-top. However, due to this one-to-one mapping, the robot's motions are limited by the user's capabilit

Cited by 0SourceScholar
2024

Automatic Spinal Canal Breach Detection During Pedicle Screw Placement

RA-L 2024

Precise pedicle screw placement is imperative for a range of spinal procedures demanding exact geometric alignment while also carrying inherent risks. The literature reports a complication rate in the case of screw mispositioning of up to 18%. To increase the accuracy of pedicle screw placement, we

Cited by 3SourceScholar
2022

Safe endoscope holding in minimally invasive surgery: zero stiffness and adaptive weight compensation

ICRA 2022poster

One of the major functions brought by robots in Minimally Invasive Surgery is endoscope holding. This consists, for the user, in placing the camera at a desired location which the robot will maintain still once he/she releases it. This behavior is usually achieved with rigid position servoing, leadi…

Cited by 0SourceScholar
2022

Using Arm Swing Movements to Maintain the Walking State in a Self-Balanced Lower-Limb Exoskeleton

ICRA 2022poster

This work investigates how arm swing movements measured by Inertial Motion Unit (IMU) sensors can be used to identify and maintain the walking state in a self-balanced lower-limb exoskeleton for medical use. When an exoskeleton is in a dynamical state during gait, short patterns in IMU signals (e.g.…

Cited by 2SourceScholar
2021

Computing the positioning error of an upper-arm robotic prosthesis from the observation of its wearer’s posture

ICRA 2021poster

When the arm prosthesis worn by an amputated Human being is not adequately configured with respect to the end-effector task, body compensations are often observed. Namely, to compensate for a wrong joint positioning on the robotic distal side, a subject trying to reach a desired position/orientation…

Cited by 5SourceScholar
2021

Intent-aware control in kinematically redundant systems: Towards collaborative wearable robots

ICRA 2021poster

Many human-robot collaboration scenarios can be seen as a redundant leader-follower setup where the human (i.e., the leader) can potentially perform the task without the assistance of the robot (i.e., the follower). Thus, the goal of the collaboration, beside stable execution of the task, is to redu…

Cited by 6SourceScholar
2020

A closed-loop and ergonomic control for prosthetic wrist rotation

ICRA 2020poster

Beyond the ultimate goal of prosthetics, repairing all the capabilities of amputees, the development line of upper-limb prostheses control mainly relies on three aspects: the robustness, the intuitiveness and the reduction of mental fatigue. Many complex structures and algorithms are proposed but no…

Cited by 14SourceScholar
2020

Fast and accurate intracorporeal targeting through an anatomical orifice exhibiting unknown behavior

ICRA 2020poster

Surgery may involve precise instrument tip positioning in a minimally invasive way. During these operations, the instrument is inserted in the body through an orifice. The movements of the instrument are constrained by interaction forces arising at the orifice level. The physical constraints may dra…

Cited by 1SourceScholar
2019

PnS: a Perspective-n-Spheres Algorithm for Laparoscope Calibration in Minimally Invasive Surgery

IROS 2019poster

Accurate endoscope localization is a key element for Computer-Assisted Laparoscopic Surgery (CALS). External localizers track the endoscope pose and reconstruct the camera geometry through a calibration matrix. Perspective-n-Points (PnP) methods estimate this matrix from a set of paired point coordi…

Cited by 1SourceScholar
2019

Safe teleoperation of a laparoscope holder with dynamic precision but low stiffness

ICRA 2019poster

A laparoscope is a key element in Minimally Invasive Surgery (MIS) as it provides visual feedback to the surgeon. To overcome the drawbacks induced by its manual operation by a human assistant, it can be fixed on the end-effector of a robotic assistant teleoperated by the surgeon: laparoscope displa…

Cited by 5SourceScholar
2019

Using comanipulation with active force feedback to undistort stiffness perception in laparoscopy

ICRA 2019poster

Surgeons performing laparoscopic surgery experience distortion when perceiving the stiffness of a patient's tissues. This is due to the lever effect induced by the introduction of instruments in their patient's body through a fulcrum. To address this problem, we propose to use the comanipulation par…

Cited by 6SourceScholar
2018

Leveraging the Fulcrum Point in Robotic Minimally Invasive Surgery

RA-L 2018

In robotic minimally invasive surgery, the incision point acts as a fulcrum around which the surgical instrument pivots. The fulcrum point has been the topic of much research. Mechanisms have been invented to enforce instrument motion about such a fulcrum. Other systems establish a fulcrum through c

Cited by 22SourceScholar
2018

Towards X-Ray Medical Imaging with Robots in the Open: Safety Without Compromising Performances

ICRA 2018poster

In this paper, a control solution featuring an energetic constraint is developed to improve the safety of a robotic manipulator sharing its workspace with humans. This general control structure, exploits a generic safe controller that ensures the respect of multiple constraints thanks to a Linear Qu…

Cited by 17SourceScholar
2017

Comparison of different error signals driving the adaptation in assist-as-needed controllers for neurorehabilitation with an upper-limb robotic exoskeleton

ICRA 2017poster

Assist-as-needed control aims at maximizing stroke survivors involvement during robotic-led therapies of neurorehabilitation. Besides the specific characteristics of the designed adaptive control strategy, a fundamental property of this control architecture is the choice of the error signal which wi…

Cited by 8SourceScholar
2015

Validation of a new method for bone motion measurement by soft-tissue artifact compensation through spatial interpolation

IROS 2015poster

Localizing a bone hidden behind soft tissue is crucial in biomechanics. A typical approach consists in placing markers on the skin, measuring their position/orientation, and from these measurements, estimating the position and orientation of the bone hidden behind the skin while compensating of soft…

Cited by 0SourceScholar