← Search

Lukas Lindenroth

12 accepted papers

2024

An MR Safe Double-Arch Needle Insertion Robot with Scissor-Folding Mechanism for Abdominal Percutaneous Interventions*

IROS 2024poster

Tumors affecting abdominal organs rank among the deadliest malignancies. In this context, Magnetic Resonance Imaging (MRI) serves as an effective diagnostic tool with a strong potential to support image-guided minimally invasive interventions for treating these tumours, offering an ionizing-radiatio…

Cited by 0SourceScholar
2023

Design and Evaluation of the SoftSCREEN Capsule for Colonoscopy

RA-L 2023

Colonoscopy is considered the golden standard for cancer screening of the lower gastrointestinal (GI) tract. Nonetheless, conventional colonoscopy can cause discomfort to patients due to the forces occurring between colonoscopes and the walls of the colon. Robotic solutions have been proposed to red

Cited by 19SourceScholar
2022

Intrinsic Force Sensing for Motion Estimation in a Parallel, Fluidic Soft Robot for Endoluminal Interventions

RA-L 2022

Determining the externally-induced motion of a soft robot in minimally-invasive procedures is highly challenging and commonly demands specific tools and dedicated sensors. Intrinsic force sensing paired with a model describing the robot's compliance offers an alternative pathway which relies heavily

Cited by 9SourceScholar
2022

Localization of Interaction using Fibre-Optic Shape Sensing in Soft-Robotic Surgery Tools

IROS 2022poster

Minimally invasive surgery requires real-time tool tracking to guide the surgeon where depth perception and visual occlusion present navigational challenges. Although vision-based and external sensor-based tracking methods exist, fibre-optic sensing can overcome their limitations as they can be inte…

Cited by 3SourceScholar
2021

A Fluidic Soft Robot for Needle Guidance and Motion Compensation in Intratympanic Steroid Injections

RA-L 2021

Intratympanic steroid injections are commonly employed in treating ear diseases, such as sudden sensorineural hearing loss or Meniere's disease through drug delivery via the middle ear. Whilst being an effective treatment, the procedure has to be performed by a trained surgeon to avoid delicate regi

Cited by 16SourceScholar
2020

A Vision-Based Soft Somatosensory System for Distributed Pressure and Temperature Sensing

RA-L 2020

Emulating a human-like somatosensory system in instruments such as robotic hands and surgical grippers has the potential to revolutionize these domains. Using a combination of different sensing modalities is problematic due to the limited space and incompatibility of these sensing principles. Theref

Cited by 14SourceScholar
2019

A2-piece six-axis force/torque sensor capable of measuring loads applied to tools of complex shapes

IROS 2019poster

Measuring forces and torques applied to tools of unconventional shapes can be challenging due to difficulties in connecting commercially available force/torque sensors. We propose an innovative, customizable six-axis force/torque sensor which can be clamped around a tool or end-effector to minimize…

Cited by 16SourceScholar
2019

Endoscope Force Generation and Intrinsic Sensing with Environmental Scaffolding

ICRA 2019poster

Endoscopic surgery is an increasingly popular alternative to laparoscopic techniques for many conditions, as the operation site can be reached without skin wounds. In many tasks, sufficient force generation is desired. As endoscopes must be highly flexible and slim, however, the force generation and…

Cited by 4SourceScholar
2017

Design of a soft, parallel end-effector applied to robot-guided ultrasound interventions

IROS 2017poster

Medical ultrasound imaging robotics systems often comprise of complex control architectures and hardware integration to enable safe human robot interaction. In this paper, we investigate the applicability of a soft robotic end-effector for ultrasound intervention. A novel, parallel design is derived…

Cited by 33SourceScholar
2017

Intrinsic force sensing capabilities in compliant robots comprising hydraulic actuation

IROS 2017poster

Knowledge of externally applied forces is crucial for compliant robotic manipulators in minimally-invasive and endoluminal robotic surgery for both patient safety and controllability of the device. We developed a novel continuum manipulator which comprises hydraulic actuation. In this work we invest…

Cited by 18SourceScholar
2016

New kinematic multi-section model for catheter contact force estimation and steering

IROS 2016poster

Contact force play is a significant role in success of the cardiac ablation. However, it is still challenging to estimate contact force when a catheter is under large bending and multiple contacts. This paper develops a new multi-section static model of the tendon-driven catheters for both real-time…

Cited by 38SourceScholar
2016

Stiffness-based modelling of a hydraulically-actuated soft robotics manipulator

IROS 2016poster

This work investigates the applicability of stiffness-based modelling in soft robotics manipulation. The methodology is introduced and applied to model a soft robotics manipulator as single 3d Timoshenko beam element. The model is then utilized to solve the forward kinematics problem for the manipul…

Cited by 45SourceScholar